AWM UL PVC CABLE

AWM UL PVC CABLE

Click to enlarge
Product Code: AWM UL PVC CABLE
      
AWM UL 2584 2095 2461 2464 2468 2509 2562 2655 2937 2570
 
○Rated Temperature: 80℃                           ○Environment: EU ROHS
 
○Rated Voltage: Between 125V to 1000V      ○Test Voltage: 1500V to 10000V
 
○Copper: Solid Stranded tinned or bare Copper
 
○Insulation Conductors: Any UL or Cul approved conductor                    
 
○Assembly : two ore more above                  ○Covering : Optional
 
○Shielding: Optional                                     ○Jacket: PVC
 
○Color:Black-White-Blue-Brown-Yellow-Green-Red-Transparence
 
     -Yellow & Green (Or Meet the client’s comment)
 
○Use:Internal wiring of electrical, electronic devices and computers.
 
Single-conductor thermoplastic insulation section 2
Rated Temperature
80℃
Rated Voltage
125V
300V
600/1000V
Style No.
2584
2095
2461
2464
2468
2509
2562
2655
2937
2570
CONDUCTOR(AWG)
32-9
30-10
26-16
26-16
32-16
---
30-16
32-6
---
≥32
Number
≥2
≥2
≥2
≥2
2-150
2-150
2-6
≥2
≥2
≥2
UL  Type or style no.
APP
APP
APP
APP
APP
APP
APP
APP
APP
APP
ASSEMBLY
 
 
 
 
 
 
 
 
 
 
Single assembly
YES
YES
YES
YES
---
YES
YES
YES
YES
YES
Multi-assembly
YES
YES
YES
YES
---
YES
YES
YES
YES
YES
SEPARATOR(S)
OPT
OPT
OPT
OPT
---
OPT
OPT
OPT
OPT
OPT
COVERING
OPT
OPT
OPT
OPT
OPT
---
---
---
OPT
OPT
SHIELDING
OPT
OPT
OPT
OPT
OPT
---
OPT
OPT
OPT
OPT
JACKET
 
 
 
 
 
 
 
 
 
 
Material
PVC
PVC
PVC
PVC
---
PVC
PVC
PVC
PVC
PVC
Diameter in (Under jacket)
Avg. jacket thickness (mm)
Cable≤17.8
---
0.81
0.81
0.81
---
0.81
0.81
0.81
0.81
0.81
17.8<Cable≤25.4
0.81
1.15
1.15
1.15
---
0.81
0.81
1.52
1.15
1.15
25.4<Cable≤38.1
1.15
1.52
1.52
1.52
---
0.81
0.81
2.03
1.52
1.52
38.1<Cable≤63.5
1.52
---
---
2.03
---
0.81
---
---
---
2.03
63.5<Cable≤101.6
---
---
---
2.79
---
---
---
---
---
2.40
BRAID
---
OPT
---
OPT
---
---
---
---
---
---
                               
●OPT : Optional.。
●≥2:Not limit to the number of conductors, the only limit being the outer diameter of the complete cable in certain case.
●APP:Each of the conductors used in the cable may have a different cross-section and style number from the others. Each conductor must be approved for a voltage and temperature that is higher than or equal to the values specified for the complete cable.
                                                                                                   
※Please contact our factory for sizes or information not listed.

Write a review

Your Name:


Your Review:
Note: HTML is not translated!


Rating: Bad            Good

Enter the code in the box below:




Protoxx Limited © 2024
Powered By SkyeyTech